ZEISS OPMI Pico

ZEISS OPMI pico is a manual, modular surgical microscope used primarily in dentistry. Its applications include endodontics, conservative dentistry, implantology and periodontics in particular. OPMI pico is available with the S100 suspension system as a floor stand, wall mount or ceiling mount. Individual configurations differ in their light source, binocular tube, objective and additional equipment, such as a video system or MORA interface.

What distinguishes ZEISS OPMI pico?

Carl Zeiss OPMI Pico is one of the most recognisable dental microscopes on the international market. Since its introduction in 2001, it has remained in the manufacturer’s range through successive versions and configurations. More than two decades on the market, a simple design and extensive configuration options have made OPMI pico well known to users and widely available on the used equipment market.

At the core of OPMI pico is a manual, 5-step magnification changer with positions of 0.4×, 0.6×, 1.0×, 1.6× and 2.5×. A rotary knob selects each step, providing simple, intuitive operation and making it easy to return to the same magnification level.

The model’s main strengths include a durable design, good ergonomics, parts availability and extensive configuration and upgrade options. The capabilities of an individual unit depend on its binocular tube, objective, illumination system, suspension type and additional equipment. In practice, its configuration also affects ergonomics and the value of the microscope.

Other models from this brand are presented on our ZEISS microscopes page.

ZEISS OPMI pico applications in dentistry

ZEISS OPMI pico is among the dental microscopes used primarily for procedures requiring magnification and good illumination of the working area. In endodontics, it allows observation of details of the pulp chamber and root canal orifices at successive stages of treatment. In conservative dentistry, it facilitates visual control of the area being prepared and the restoration being carried out.

The microscope is also used in selected implantology and periodontics procedures. The orange filter can be used when working with light-curing materials because it reduces premature curing. The green filter increases contrast in the observed image.

OPMI pico is also used in ENT (Otolaryngology), gynecology and general surgery, among other fields.

Key technical specifications of ZEISS OPMI pico

OPMI pico is available in many configurations. The table below presents the model’s main parameters and available equipment variants.

Main parameters and equipment variants of ZEISS OPMI pico
ComponentAvailable variants or parameters
Magnification adjustmentmanual, 5-step mechanism: 0.4×; 0.6×; 1.0×; 1.6×; 2.5×
Total magnification1.7×–26.6× (determined by the magnification changer setting, objective focal length, binocular tube and eyepieces)
Eyepieces10× or 12.5× widefield eyepieces
Binocular tubesstraight 0°, inclined 45°, tiltable 0–180° or foldable ZEISS Foldable Tube f170/f260
Fixed focal length objectives200, 250, 300, 350 or 400 mm
Objectives with fine focus200, 250 or 300 mm
Varioskop 100adjustable working distance of 200–300 mm
Illuminationhalogen, xenon or LED, depending on the configuration
Filtersorange and green
S100 suspension systemfloor stand, wall mount, ceiling mount, workplace integration version (support unit) or adaptation to the Centro system
MORA interfaceoptional equipment that increases the microscope head’s tilt range; also available with a lateral port for connecting a video system
Camera and video systemoptional equipment for observation, image recording and transmission

How to choose an OPMI pico configuration

When choosing an OPMI pico, the most important consideration is matching its equipment to the user’s specialty and working method. The binocular tube, objective and additional equipment affect the ergonomics, capabilities and price of the microscope.

Basic configuration for ENT and dentistry

In ENT, the basic and least expensive configuration is a straight binocular tube 0° combined with a fixed focal length objective. In dentistry, the practical minimum is an inclined binocular tube 45° and at least an objective with fine focus.

These combinations allow users to start working with OPMI pico and can be a suitable choice when buying a first microscope. Each addition beyond the basic configuration can improve ergonomics, increase the adjustment range or extend functionality, but it also affects the price. Not every user needs a Varioskop, a 0–180° binocular tube, a video system or a MORA interface from the outset.

How to choose a binocular tube for OPMI pico

The straight binocular tube 0° is the basic option, most often found in configurations intended for ENT. In dentistry, the usual starting point is an inclined binocular tube 45°, which provides a suitable viewing position while retaining a relatively simple design.

A tiltable binocular tube 0–180° offers greater freedom to adjust the viewing angle and makes it easier to adapt the microscope to the operator’s height, the patient’s position and the treatment area. The foldable ZEISS Foldable Tube f170/f260 provides an even wider adjustment range. Its articulated design offers more ways to adjust the viewing position, while the PROMAG function allows magnification to be increased temporarily to 150% of the set value.

Microscope head handle variants

OPMI pico can be fitted with several types of handles for positioning and guiding the microscope head, including front, rear, T-shaped and adjustable comfort handles. The handle type does not change the microscope’s optical parameters, but it affects positioning and ease of use. Adjustable comfort handles can be adapted to the user’s preferences and working method.

ZEISS MORA interface – greater freedom of positioning

The ZEISS MORA interface is an optional component intended for dental configurations. It allows lateral tilting of the microscope head, making it easier to change the viewing angle without the operator having to change position. MORA is also available with a lateral port for connecting a video system. It is not essential for starting work, but it can significantly improve ergonomics and increases the value of the complete configuration.

Fixed or variable focal length objective?

OPMI pico can be fitted with a fixed focal length objective in a standard version or with fine focus. With the standard version, focus is adjusted by moving the microscope head relative to the working area. Fine focus allows precise focusing over a small range without repositioning the entire head.

In ENT, a standard fixed focal length objective is often sufficient. In dentistry, we recommend a fixed focal length objective with fine focus as the practical minimum for starting work.

An alternative is the variable focal length Varioskop 100, which allows adjustment of the working distance within a range of 200–300 mm. It makes it easier to change the focus point without moving the microscope head and offers greater freedom in positioning the microscope, but also increases the value of the complete configuration.

Halogen, LED or xenon?

OPMI pico is available with halogen, LED or xenon illumination. Halogen is the most common light source in units available on the used equipment market. It is a proven and economical solution that is relatively straightforward to use, so it should not be regarded as a drawback of a used microscope. The condition of the lamp and light guide is important when assessing such a configuration.

LED illumination is found primarily in newer configurations and is the current standard in new units. It provides light with characteristics similar to daylight, emits little heat and requires limited maintenance.

Xenon is much less common. It provides intense light with a colour temperature of approximately 5000 K, but involves higher running costs. It is a higher-end option whose capabilities are not needed by every user. The type of illumination affects both working comfort and the price of the complete configuration.

ZEISS S100 suspension system variants

The S100 suspension system is available in several variants that differ primarily in installation method and the ability to move the microscope. The suspension type does not affect optical quality, but it is important for the organisation of the workstation.

The floor stand version is the most common on the used equipment market and in Medical Elektro’s range. It allows the microscope to be positioned freely by the chair and moved between workstations. However, a floor stand requires sufficient space around the chair.

The wall mount version leaves the floor space free, but requires fixed installation and advance planning of the microscope’s position and arm reach. It can be a good solution for a practice where the microscope stays at one workstation.

A ceiling mount also leaves the floor space free, but requires suitable preparation of the mounting location and installation. ZEISS also provides for adapting S100 to the Centro system and offers a workplace integration version (support unit) for more specialised workstation arrangements. The choice should depend primarily on the practice layout and the intended use of the microscope.

Integrated or external camera?

A video system is optional equipment whose usefulness depends on how procedure images are recorded and presented. Depending on the version, the microscope can have an integrated camera or be upgraded with an external camera. The system allows an assistant to view the image and enables image recording and transmission to a monitor or network.

An integrated camera is matched to the microscope’s design and does not require additional components to be mounted on the head. An external camera allows a simpler configuration to be upgraded, but its weight may affect the microscope’s balance. A video system increases the functionality and value of the setup, although not every user needs one from the outset.

Connecting a digital camera

OPMI pico can also be upgraded with a digital camera for taking photographs, recording video and displaying a live image on a monitor. Installation requires a beam splitter and a suitable adapter matched to the camera. Additional components mounted on the head may affect its balance, so the microscope should be correctly adjusted after the upgrade.

Need help choosing a configuration? Tell us which specialty the microscope will be used in and how you plan to use it. We will help assess which components are needed at the start and which can remain optional. Ask about choosing a configuration.

What determines the price of a used ZEISS OPMI Pico microscope?

On the used equipment market, the price of a used ZEISS OPMI Pico microscope depends on the technical condition, completeness and configuration of the individual unit, including the S100 suspension system variant, binocular tube, objective, light source and the presence of a MORA interface and video system. At Medical Elektro, all units are prepared to the same refurbishment standard, so the level of preparation does not vary between offers or affect pricing. The price is determined individually for the complete configuration.

Refurbished ZEISS OPMI Pico microscopes at Medical Elektro

“Used” means that the microscope has previously been operated. A refurbished surgical microscope is a used unit that has undergone a multi-stage process to prepare it for sale.

Refurbishment at Medical Elektro follows one standard covering the complete configuration of each individual unit. For ZEISS OPMI Pico, this includes the complete microscope with the appropriate S100 suspension system variant and the unit’s actual optical, illumination, mechanical and video equipment. Every refurbished unit has individual photographs and a description matching its configuration, and comes with a 12-month warranty. The full scope is described on our surgical microscope refurbishment process page.

ZEISS OPMI Pico microscope availability

The list of ZEISS OPMI Pico units is updated automatically. Availability and details of the S100 suspension system variant, binocular tube, objective, light source and video equipment are provided for each unit.

Contact Medical Elektro about choosing a ZEISS OPMI Pico, the equipment of available units and an individual quotation.